Orion-system OE217-00 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Sensoren Orion-system OE217-00 herunter. Orion System OE217-00 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 38
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Form: ORION-OE217-01-DigitalRoomSensor-1C.doc Page 1 of 1
Description
The OE217 series of Touch Screen Digital Room Sensors
are used to sense Space Temperature only or Space
Temperature & Space Humidity. The OE217-00 model is
the Space Temperature Sensor only model and can be
used with the VCM-X Controller (OE332-23-VCMX) and
the VAV/Zone Controller (OE324-02). The OE217-01 is a
combination Space Temperature & Space Humidity
Sensor model and can only be used with the VCM-X
Controller.
Besides sensing Temperature & Humidity, the Digital
Room Sensors also provide these other useful features:
User Friendly Graphical LCD Display with LED
Backlight
Display the Current Space and Outdoor Air
Temperature
Display the Current Space Humidity and Outdoor
Air Relative Humidity (OE217-01 Model Only)
Display the current Zone Setpoint Temperature
Equipped With Push Buttons for Changing the
Zone Setpoint Temperature
Equipped With an Override Button for Forcing the
VAV/Zone Controller or VCM-X Controller into
Occupied Operation from Unoccupied Operation
Provides graphics to indicate the mode of operation
Provides LEDs to indicate Schedule Override,
Button Push, and Alarms
Both sensors connect to the controllers using TSDRSC
modular cables of multiple lengths connected between the
controller and the sensor. The TSDRSC modular cables
should not run in conduit with other AC line voltage wiring
or with any conductors carrying highly inductive loads.
Mounting
The Digital Room Sensor is designed to be mounted to a vertical, 2” x 4” electrical box recessed in the wall. If the wall
cannot be penetrated, a plastic surface mount box such as those made by Wiremold
TM
, may be used to mount the
sensor to the wall surface. The Sensor is mounted by removing the front cover and fastening the housing base to the
electrical box using the supplied (2) 6/32” x 1” machine screws. The Modular cable is then plugged into the phone jack
located on the circuit board that is mounted on the cover. The cover is then placed onto the housing base and the Allen
Screw on the bottom of the base is adjusted to hold the cover in place.
Technical Data OE217-00 & OE217-01 Digital Room Sensor
Sensor Element Type III Thermistor 10k ohm
@ 77 F Digital Sensing Device
Display 112 x 64 Monochrome Graphical LCD
w/LED Backlight
Sensor Reading
Range
40F to 120F
RH = 0-100%
Connection
RJ-45 Modular Female Jack
Ambient
Temperature
Limits
-40F to 180F
Weight
3.2 oz.
Accuracy
RH +/-2%, Temp +/- .5F
Three Year Warranty WattMaster reserves the right to change specifications without notice
OE217-00 & OE217-01
Digital Room Sensors
Seitenansicht 0
1 2 3 4 5 6 ... 37 38

Inhaltsverzeichnis

Seite 1 - Digital Room Sensors

Form: ORION-OE217-01-DigitalRoomSensor-1C.doc Page 1 of 1 Description The OE217 series of Touch Screen Digital Room Sensors are used to sense Spac

Seite 2 - TSDRSC-XX

Form: ORION-ModularRoomSensor-1F.doc Page 1 of 1 Description The patented design, OE21x-02 series Modular Room Sensor provides accurate sensing o

Seite 3 - E-BUS Digital Room Sensors

Form: ORION-ModularCable-FMRSC-1B.doc Page 1 of 1 Description Description The FMRSC Cables are used to connect power and communica-tions between

Seite 4 - E-BUS Digital Room Sensor

Form: ORION-StandardRoomSensor-1D.doc Page 1 of 1 Description The patented design, OE21x series Standard Room Sen-sor provides accurate sensing of

Seite 5

FILENAMEDATE:B. CREWSDESCRIPTION:PAGEDRAWN BY:Duct Temperature Sensor1JOB NAME07/13/15G-DUCSENS1.CDROE230 & OE231Duct Temperature SensorsOE230 (6&

Seite 6 - MS000248 - E-BUS Adapter Hub

4.)All Wiring To Be In Accordance WithLocal And National Electrical CodesAnd Specifications.3.)Gasket Must Be Installed Under CoverPlate To Provide Ra

Seite 7

Form: Orion-OE265-15-A-EBUS-Horiz-OA-RH-Sensor-01A Page 1 of 1 Description The OE265-15-A E-BUS Horizontal Outdoor Air Temperature and Humid

Seite 8

Form: Orion-OE265-16-EBUS-Vert-OA-RH-Sensor-01B Page 1 of 1 Description The OE265-16 E-BUS Vertical Outdoor Air Temperature and Humidity is

Seite 9 - EBC-XXXF – EBC E-BUS Cables

Form: ORION-OE265-17-A-EBUS-Return-RH-Sensor-01A Page 1 of 1 Description The OE265-17-A E-BUS Return Air Temperature and Humidity is a combin

Seite 10 - Modular Room Sensors

JOB NAMEFILE NAMEG-OE265-13B-OAHUMID-1F.PDFDATE: 08/25/11PAGEDESCRIPTIONOutside Air Humidity Sensor – 0-5 VDCDRAWN BY: B. CREWSNotes:1.) The Outsid

Seite 11 - Modular Room Sensor Cable

JOB NAMEFILE NAMEPAGEDESCRIPTIONOE265-13 BAPIOutside Air Humidity Sensor – 0-5 VDCDRAWN BY: B. CREWS2 of 2Notes:1.) All Wiring To Be In Accordance

Seite 12 - Standard Room Sensors

Form: ORION-ModularCable-TSDRSC-1A.doc Page 1 of 1 Description The TSDRSC Cables are used to connect power and communica-tions between the WattMa

Seite 13 - Duct Temperature Sensors

JOB NAMEFILE NAMEG-OE265-14B-RAHUMID-1D.PDFDATE: 08/28/07PAGEDESCRIPTIONOE265-14 BAPIReturn Air Humidity Sensor – 0-5 VDCDRAWN BY: B. CREWSNotes:1.

Seite 14 - Outside Air Sensor OE250

JOB NAMEFILE NAMEPAGEDESCRIPTIONReturn Air Humidity Sensor – 0-5 VDCDRAWN BY: B. CREWS2 of 2 RH Output % VDC55 ... 2.7560 ... 3.0065 .

Seite 15

JOB NAMEFILE NAMEG-OE265-11-SPHUMID1D.PDFDATE: 08/02/07PAGEDESCRIPTIONOE265-11Space Humidity Sensor – 0-5 VDCDRAWN BY: B. CREWSNotes:1.) The senso

Seite 16 - Mounting

JOB NAMEFILE NAMEG-OE265-11-SPHUMID1D.PDFDATE: 08/02/07PAGEDESCRIPTIONOE265-11Space Humidity Sensor – 0-5 VDCDRAWN BY: B. CREWS*Chart Notes:1. Fi

Seite 17

Form: ORION-OE265-06-Humidistat-1C.doc Page 1 of 1DescriptionThe OE265-06 Wall Mounted Humidistatis used with the HVAC unit controller toinitiate deh

Seite 18 - INCORRECT

Form: ORION-OE265-07-Humidistat-1B.doc Page 1 of 1DescriptionThe OE265-07 Duct MountedHumidistat is used with theHVAC unit controller to initiatedehum

Seite 19 - RH/Voltage Chart

4.)AllWiringToBeInAccordanceWithLocalAndNationalElectricalCodesAndSpecifications.3.)GasketMustBeInstalledUnderCoverPlateToProvideRaintightSeal.Rainwat

Seite 20 - Sensor to Duct

CONTROLSFILENAMEDATE: 01/03/05B. CREWSDESCRIPTION:PAGEDRAWN BY:G-OE233-W-TempSnsr1a.CDROE233 - Strap-On TemperatureSensor Kit Installation1JOB NAMEPla

Seite 21

Notes:CONTROLSFILENAMEDATE:B. CREWSDESCRIPTION:PAGEDRAWN BY:Static Pressure Pickup Tube1JOB NAME05/21/00SPUTUBE1.CDROE290In Order To Obtain Accurate S

Seite 22 - Right Side View

FILENAMEDATE:B. CREWSDESCRIPTION:PAGEDRAWN BY:Water Temperature Sensor Thermowell1JOB NAME07/09/04G-OE291-T-Well.CDROE291OE291 Thermowell AssemblyUsin

Seite 23

Form: ORION-OE217-02-03-EBUS-DRS-1A.doc Page 1 of 1 Description The OE217 series of Touch Screen E-BUS Digital Room Sensors are used to sense Spa

Seite 24 - Humidistat

General NotesFILENAMEDATE:B. CREWSDESCRIPTION:PAGEDRAWN BY:Pressure Sensor1JOB NAME2.)All Wiring To Be In Accordance With Local AndNational Electrical

Seite 25 - OE265-07 – Duct Mounted

Notes:CONTROLSFILENAMEDATE:B. THRALLDESCRIPTION:PAGEDRAWN BY:Pressure Independent Velocity Sensor1JOB NAME2.)All Wiring To Be In Accordance With Local

Seite 26 - AmbientLightSensor OE259

Form: ORION-OE258-6-BuildingPressureSensor-1B.docPage 1 of 1DescriptionThe OE258 Building Static Pressure Sen-sor is used to sense building pressure i

Seite 27 - CONTROLS

Form: ORION-OE256-01-CO2Sensor-1C.doc Page 1 of 1 Description The OE256-01 Wall Mounted CO2 Sensor is used in conjunction with the VCM-X Control

Seite 28 - SPUTUBE1.CDR

Form: ORION-OE256-02-DuctMtdCO2Sensor-1A.doc Page 1 of 1 Description The OE256-02 Duct Mounted CO2 Sensor is used in conjunction with the VCM-X C

Seite 29 - OE291 Thermowell Assembly

Form: AAON-OE256-05—EBUS-CO2Sensor-1A.doc Page 1 of 1 Description The Wall Mounted E-BUS CO2 Sensor (Orion Part No. OE256-05; AAON Part No. V093

Seite 30 - Airflow Sensor

Form: AAON-OE256-07-EBUS-DUCT-CO2-1B.doc Page 1 of 1 Description The E-BUS Duct Mounted E-BUS CO2 Sensor with Remote Pickup (Orion Part No. OE256

Seite 31 - Side View

Form: ORION-OE275-01-SuctionPressureTransducer-1E.doc Page 1 of 1DescriptionThe OE275-01 Suction Pressure Trans-ducer is used to monitor the suction l

Seite 32

Form: ORION-OE275-03-A-SuctionPressureSensorKit-wE-BUS-Adapter-1B.doc Page 1 of 1 Description The OE275-03-A Suction Pressure Sensor Kit wit

Seite 33

Form: ORION-OE217-04-EBUS-DRS-1A.doc Page 1 of 1 Description The OE217-04 E-BUS Digital Room Space & Humidity Sensor is used to sense Space

Seite 34

Form: ORION-BK000081-Sensor-Mounting-Plate-1A.doc Page 1 of 1 Description The BK00081 Sensor Mounting Plate is used, if necessary, to cover

Seite 35

Form: AAON-MS000248-E-BUS-Adapter-1A.doc Page 1 of 1 Description The MS000248 E-BUS Adapter Hub is used to provide a connection point for

Seite 36

Form: AAON-HZ-EBC-248-E-BUS-Adapter-1A.doc Page 1 of 1 Description The HZ-EBC-248 (AAON Part No. V17180) is comprised of the MS000248 E-BUS

Seite 37

Form: ORION-OE365-15-EBA-A-E-BUS-Adapter-Board-1C.doc Page 1 of 1 Description The OE365-15-EBA-A E-BUS Adapter Board is used to provide a co

Seite 38 - With E-BUS Adapter Board

Form: ORION-EBC-XXXF-E-BUS-Cable-1B.doc Page 1 of 1 Description The EBC E-BUS Cables are used to connect power and communications between the VCB

Verwandte Modelle: OE217-01